Customization: | Available |
---|---|
Transport Package: | High-Qiality Carton |
Trademark: | Infitek |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Double Reagents
Items | Cat. | Product | Short Name | Size | Format | Method | |
R1 | R2 | ||||||
Liver Function | 2000 | ALT/GPT | ALT | 60ml×4 | 60ml×2 | Liquid | IFCC |
2010 | AST/GOT | AST | 60ml×4 | 60ml×2 | Liquid | IFCC | |
2020 | ALP | ALP | 60ml×3 | 45ml×1 | Liquid | IFCC | |
2030 | γ-GT (GGT) | GGT | 60ml×3 | 36ml×1 | Liquid | Szasz | |
2120 | Total Bilirubin | TB | 60ml×4 | 12ml×4 | Liquid | Diazonium | |
2125 | Total Bilirubin | TB | 60ml×4 | 15ml×4 | Liquid | Vanadate | |
2130 | Direct Bilirubin | DB | 65mlx2 | 8mlx4 5mlx1 | Liquid | Diazonium | |
2135 | Direct Bilirubin | DB | 60ml×4 | 15ml×4 | Liquid | Vanadate | |
2140 | Total Protein | TP | 60mlx4 | Liquid | Biuret | ||
2150 | Albumin | ALB | 60mlx4 | Liquid | Bromine Cresol Chlorine | ||
2275 | Total Bile Acids | TBA | 60mlx2 | 20mlx2 | Liquid | Enzymatic Cycling | |
2285 | ADA | ADA | 50ml×1 | 25ml×1 | Liquid | Enzymatic Kinetic | |
2471 | LAP | LAP | 24mlx2 | 12mlx1 | Liquid | L-leucine-p-nitroaniline substrate method | |
9055 | PA | PA | 60mlx1 | 12mlx1 | Liquid | Immuno Turbidimetric | |
Kidney Function | 2110 | Uric Acid | UA | 60mlx2 | 30mlx2 | Liquid | Urease/Peroxidase |
2070 | Urea | UREA | 60ml×4 | 60ml×2 | Liquid | Urease | |
2170 | Creatinine | CREA | 60mlx4 | 50mlx1 | Liquid | Picrate | |
2175 | Creatinine | CREA | 60mlx2 | 30mlx2 | Liquid | SOD Enzymatic | |
9085 | Cys-C | Cys-C | 50mlx1 | 50mlx1 | Liquid | Immuno Turbidimetric | |
9086 | Cys-C | Cys-C | 60mlx1 | 15mlx1 | Liquid | Latex Immuno Turbidimetric | |
9140 | RBP | RBP | 45mlx1 | 15mlx1 | Liquid | Immuno Turbidimetric | |
9060 | U-mALB | U-mALB | 60mlx2 | 12mlx1 | Liquid | Immuno Turbidimetric | |
Rheumatism | 9035 | CRP | CRP | 60mlx1 | 15mlx1 | Liquid | Immuno Turbidimetric |
9105 | ASO | ASO | 40mlx1 | 60ml×1 | Liquid | Immuno Turbidimetric | |
9110 | RF | RF | 60mlx1 | 20mlx1 | Liquid | Immuno Turbidimetric | |
Blood Lipid | 2080 | Cholesterol | CHO | 60ml×4 | 60ml×2 | Liquid | CHOD-PAP |
2090 | Triglyceride | TG | 60ml×3 | 30ml×1 | Liquid | GPO-PAP | |
2238 | Direct-HDL-C | HDL | 60ml×4 | 20ml×4 | Liquid | Clearance | |
2248 | Direct-LDL-C | LDL | 60ml×4 | 20ml×4 | Liquid | Clearance | |
9000 | ApoA1 | ApoA1 | 60mlx1 | 20mlx1 | Liquid | Immuno Turbidimetric | |
ApoB | ApoB | 60mlx1 | 20mlx1 | Liquid | Immuno Turbidimetric | ||
9065 | Lp(a) | Lp(a) | 70mlx1 | 10mlx1 | Liquid | Immuno Turbidimetric | |
9066 | Lp(a) | Lp(a) | 60mlx1 | 15mlx1 | Liquid | Latex Immuno Turbidimetric | |
9120 | D-Dimer | DD | 60mlx1 | 20mlx1 | Liquid | Immuno Turbidimetric | |
Glycometabolism | 2100 | Glucose | GLU | 60ml×3 | 45ml×1 | Liquid | GOD-PAP |
2106 | Glucose | GLU | 60ml×4 | 15ml×4 | Liquid | HK | |
9130 | HbA1C | HbA1C | 60mlx1 | 19mlx1 1mlx1 | Liquid | Immuno Turbidimetric | |
2340 | GSP | GSP | 14mlx6 | 6mlx6 | Liquid | NBT | |
Myocardium Zymogram | 2040 | CK-NAC | CK | 60mlx2 | 30mlx2 | Liquid | IFCC |
2045 | CK-MB | CK-MB | 20mlx4 | 10mlx4 | Liquid | Immuno-inhibition | |
2050 | LDH-L | LDH | 60mlx3 | 54mlx1 | Liquid | L-P | |
2060 | α-HBDH | α-HBDH | 30mlx3 | 22.5mlx1 | Liquid | DGKC | |
2300 | HCY | HCY | 60mlx1 | 19mlx1 | Liquid | Enzymatic Cycling | |
Pepsinogen | 9040 | PG I | PG I | 50mlx1 | 10mlx1 | Liquid | Immuno Turbidimetric |
9045 | PG II | PG II | 50mlx1 | 10mlx1 | Liquid | Immuno Turbidimetric | |
Pancreas | 2220 | α-Amylase | α-Amy | 50mlx2 | 10mlx2 | Liquid | EPS |
Blood Gas Electrolyte | 2160 | Calcium | Ca | 60ml×4 | 60ml×4 | Liquid | OCPC |
2183 | Phosphorous | P | 60mlx2 | 27mlx2 | Liquid | Molybdate | |
2190 | Magnesium | Mg | 50mlx2 | 50mlx2 | Liquid | Xylidy Blue | |
2311 | Potassium (K) | K | 45mlx1 | 15mlx1 | Liquid | Pyruvate Kinase | |
2321 | Sodium (Na) | Na | 45mlx1 | 15mlx1 | Liquid | Pyruvate Kinase | |
2331 | Chloride (CL) | CL | 60ml×3 | Liquid | Mercuric Thiocyanate | ||
2380 | Lithium (Li) | Li | 20mlx2 | 10mlx2 | Liquid | Enzymatic | |
2260 | CO2 | CO2 | 21mlx4 | 7mlx5 | Liquid | Enzymatic | |
Special Protein | 9005 | IgG | IgG | 60mlx1 | 20mlx1 | Liquid | Immuno Turbidimetric |
9010 | IgA | IgA | 60mlx1 | 20mlx1 | Liquid | Immuno Turbidimetric | |
9015 | IgM | IgM | 60mlx1 | 20mlx1 | Liquid | Immuno Turbidimetric | |
9020 | C3 | C3 | 60mlx1 | 20mlx1 | Liquid | Immuno Turbidimetric | |
9025 | C4 | C4 | 60mlx1 | 20mlx1 | Liquid | Immuno Turbidimetric | |
9030 | TF | TF | 15mlx2 | 10mlx1 | Liquid | Immuno Turbidimetric | |
2360 | PCT | PCT | 21mlx1 | 7mlx1 | Liquid | Immuno Turbidimetric | |
9116 | hs-CRP | hs-CRP | 60mlx1 | 60mlx1 | Liquid | Immuno Turbidimetric | |
Nutrition | 9180 | 25-OH-VD | 25-OH-VD | 17ml*1 | 17ml*2,17ml*1 | Liquid | Latex Immuno Turbidimetric |
Cat. | Product | Size | Format | Test Items Range |
4011 | 21 Assays Multi- QC (Level 1, Abnormal, Low Value) | 3ml×10 | Lyophilized Powder | K, Na, Cl, Ca, P, UA, Glu, Urea, Cre, TP, Alb, CHO, TG, ALP, ALT/GPT, AST/GOT, CK, LDH, γ-GT, α-HBDH, α-Amylase |
4022 | 21 Assays Multi-QC (Level 2, Normal, Medium Value) | 3ml×10 | Lyophilized Powder | K, Na, Cl, Ca, P, UA, Glu, Urea, Cre, TP, Alb, CHO, TG, ALP, ALT/GPT, AST/GOT, CK, LDH, γ-GT, α-HBDH, α-Amylase |
4031 | 21 Assays Multi-QC (Level 3, Abnormal, High Value) | 3ml×10 | Lyophilized Powder | K, Na, Cl, Ca, P, UA, Glu, Urea, Cre, TP, Alb, CHO, TG, ALP, ALT/GPT, AST/GOT, CK, LDH, γ-GT, α-HBDH, α-Amylase |
4320 | Multi-Calibrator / Standards (21 items) | 1mlx3 | Lyophilized Powder | ALT,AST,GGT,ALP,AMY,CK,LDH,Glu,Urea,UA,Cre,T.Bili,D.Bili,P,Ca,Iron,Mg,CHO,TG,TP,Alb |
4330 | Multi-QC (Level 1, Normal Value) (23 items) | 1mlx3 | Lyophilized Powder | ALT,AST,GGT,ALP,AMY,CK,LDH,Glu,Urea,UA,Cre,T.Bili,D.Bili,P,Ca,Iron,Mg,CHO,TG,TP,Alb |
4334 | Multi-QC (Level 2, Abnormal Value) (23 items) | 1mlx3 | Lyophilized Powder | ALT,AST,GGT,ALP,AMY,CK,LDH,Glu,Urea,UA,Cre,T.Bili,D.Bili,P,Ca,Iron,Mg,CHO,TG,TP,Alb |
4375 | Lipid Multi-QC (Level 1, Abnormal, Low Value) (7 items) | 1mlx3 | Lyophilized Powder | Direct HDL-C, Direct LDL-C, Triglyceride, Cholesterol, APO A, APO B, Lp(a) |
4385 | Lipid Multi-QC (Level 2, Normal, Medium Value) (7 items) | 1mlx3 | Lyophilized Powder | Direct HDL-C, Direct LDL-C, Triglyceride, Cholesterol, APO A, APO B, Lp(a) |
4395 | Lipid Multi-QC (Level 3, Abnormal, High Value) (7 items) | 1mlx3 | Lyophilized Powder | Direct HDL-C, Direct LDL-C, Triglyceride, Cholesterol, APO A, APO B, Lp(a) |
3430 | Biochemical Calibrator (30 items) | 3ml*3 | Lyophilized Powder | Alb,ALP,ALT,AMY,AST,Ca,CHE,CHO,CK,Cre (Jaffe/Enzymatic),D.Bili (Diazonium/Vanadate),GGT,GLDH,Glu (GOD/HK),a-HBDH,Iron,LDH,LPS,Mg,IP,P-AMY,T.Bili (Diazonium/Vanadate),TG,TP,UA,Urea |
4720 | Multi-QC Level 1 (52 items) | 3ml*1 | Lyophilized Powder | Alb,ALP,ALT,AMY,AST,Ca,CHE,CHO,Cre (Jaffe/Enzymatic),D.Bili (Diazonium/Vanadate),GGT,GLDH,Glu (GOD/HK),a-HBDH,Iron,LDH,LPS,Mg,IP,P-AMY,T.Bili (Diazonium/Vanadate),TG,TP,UA,Urea,CK-NAC,CK-MB,CRP, HS-CRP,HDL-C,LDL-C,APOA1,APOB,C3,C4,ASO,TF,HP,AAG,Cl,Fe,Li,Mg,K,Na,FER,IgG,IgA,IgM |
4722 | Multi-QC Level 2 (52 items) | 3ml*1 | Lyophilized Powder | Alb,ALP,ALT,AMY,AST,Ca,CHE,CHO,Cre (Jaffe/Enzymatic),D.Bili (Diazonium/Vanadate),GGT,GLDH,Glu (GOD/HK),a-HBDH,Iron,LDH,LPS,Mg,IP,P-AMY,T.Bili (Diazonium/Vanadate),TG,TP,UA,Urea,CK-NAC,CK-MB,CRP, HS-CRP,HDL-C,LDL-C,APOA1,APOB,C3,C4,ASO,TF,HP,AAG,Cl,Fe,Li,Mg,K,Na,FER,IgG,IgA,IgM |
3370 | RBP's | 1ml×5 | Liquid | RBP |
4500 | RBP QC Level 1 | 2ml×1 | Liquid | RBP |
4505 | RBP QC Level 2 | 2ml×1 | Liquid | RBP |
3405 | Cys-C's (latex) | 1ml×5 | Liquid | Cys-C |
4735 | Cys-C QC | 1ml×2 | Liquid | Cys-C |
4655 | LAP QC ( level 1 level 2 ) | 5mlx2 | Lyophilized Powder | LAP |
3525 | CRP Calibrator | 2mL×5 | Liquid | CRP |
3320 | HbA1c Calibrator | 0.5mL×4 | Lyophilized Powder | HbA1c |
3310 | RF Calibrator | 1mL×5 | Liquid | RF |
3425 | Calibrator for Specific Protein (8 items) | 1ml*6 | Liquid | IgA, IgG, IgM, TF, HP, C3, C4,AAG |
9807 | Lp(a)'s(latex) | 1ml×5 | Lyophilized Powder | Lp(a) |
Q: Can QPCR be used directly upon arrival? Does new machine need calibration after transporation ?
A: It need to be unlock first when arrive . There is video instruction. No need calibartion .
Q: What is the requirment of PC when install software ?
A: It need Win10 system PC. For new PC, it need to install a driver before install software. During the runing of software, PC screen need to keep on , not use dormant status.
Q: What is the difference between 4 channel and 6 channel model ?
A: PCR-RT-96-6 has six detection channels. PCR-RT-96-4 has five detection channels. They all have 2 duplicated for same dyes SYBR / FAM. PCR-RT-96-4 have one channel extra - Cy3/NED/TAMRA
Q: What is the difference between Standard and Fast mode for Melting curve?
A: Both model QPCR have 2 FAM/SYBR channel. For SYBR , in melting curve FAST Mode, the 2 FAM channel will be open at same time and detection time will be shorter than standard mode. But FAST mode cannot be used in Taqman probe mode.
Q: Can we adjust the voltage(Gain value )of PMT Setting of different channel ?
A: It cannot adjust the voltage of each channel , but we can adjust the light path with 3levels accordng to customer requirement to meet the demand of different signal intensity.
Q: What is the Scanning method?
A: From the top to scan each tube in sequence. The advantage is - avoid the crosstalk and get accurate fluorescence value.
Q: What is the door direction ?
A: QPCR door is at front side of machine.
Q: Does QPCR result need to be corrected by ROX ?
A: Not need
Q: What is the Detection device of QPCR? What light source and how many?
A: The detection device is PMT. The light source is LED. X6-6 X4-5
Q: What is the difference between PMT and CCD detection
A: PMT is highly sensitive signal detector. The detector scans the fluorescence signal of each well separately. It can effectively reduce fluorescent crosstalk. CCD is like a high-sensitivity camera.It collects fluorescence values of all well positions at once.It takes less time.
Q: What is the sample volume ?
A: 10-50ul
Q: What size tube can be used on QPCR ?
A: Recommend 100ul PCR tube or low profile 200ul tube. If use 200ul high profile tube , it will appear steam in the tube which may affect the test result. If must use 200ul high profile tube, suggest to add paraffin oil .
Q: It only has Second unit when we set the timer, can we have option of Minute ?
A: The length of gene is usually 200bp, time required as Seconds level. Only in RT test , Minute is needed . Will consider to add Minute unit in future.
Q: Can we edit program while QPCR run the program ?
A: Cannot edit .
Q: During PCR running , how to check the previous test result ?
A: Click 'File- Open in frame '
Q: What is the ordinate of the amplification curve currently showing?
A: In the latest version of the software, the original fluorescence value, Rn value and the normalized fluorescence value curve can be displayed.
Q: In the absolute quantitative test, can result analysis show the average value and deviation?
A: It need to tick out Replicate (in sample setting interface) when set Replicate sample and standard sample as the same value , then it appears average value during analysis , but cannot show the deviation value.
Q: Can user delete those unnormal results whe make the standard curve ?
A: The software does not support direct edit after test , user can output the CT value data and edit it in excel, then make the standard curve in excel.
Q: How to avoid the wrong setting or miss-selection of channels ?
A: Software doesnot support analysis after result, Suggest user to tick out all the channels during setting.
Q: How to adjust the threshold value ?
A: Select Spine method, threshold line will appear and can be adjusted
Q: What is the suitable value of Threshold line ?
A: For Linearity curve , put it at inflection point. For logistic curve, put it at straight line place
Q: The application result is normal why data cannot output ? Why the aplication curve cannot display when tick out the reaction tubes position ?
A: Check the Return at the right corner of Amplification interface, click Return then can operate.
Q: Can user define the color of amplification curve ?
A: CAN NOT
Q: How to adjust the start point of baseline after test end ?
A: The baseline has been automatically corrected , not need to adjust . The latest version of the software provide the option of baseline adjustment.
Q: How to solve the issue that signal value reach to upper limit at platform stage?
A: Can adjust the concentration of fluorescene marker or set the PMT detection as Low level .
Q: Can we use Molecular beacon to do melting curve ?
A: Hardware can support this test, but software doesnot have this analysis function, will be added in the next version software.
Q: Does QPCR have HRM analysis ?
A: The software is not supported currently
Q: What need to be attention when move the instrument ?
A: Before move the instrument , put the machine in 96 well protection plate and lock the machine. Refer to the Lock operation video.