Overview

Basic Info.

Model NO.
BEP-M120, BEP-M130, BEP-M131
Portable
Portable
Appliance
Food Analysis, Medical Research, Biochemistry
Range
-2.000~20.000pH
Resolution
0.001, 0.01pH Selectable
Accuracy
0.002pH
Transport Package
Carton
Trademark
Infitek
Origin
China
Production Capacity
10000 Units/Month

Product Description

Infitek Bep-M Series Benchtop pH Lon ORP Water Hardness Meter
Infitek BEP-M Series Benchtop pH lon ORP Water Hardness meter
Features


Measurement Parameters
• BEP-M120: pH, mV, relative mV, temperature
• BEP-M130: pH, mV, relative mV, ion concentration, water hardness, temperature
• BEP-M131: Ion concentration, water hardness, mV, temperature
Features
pH
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers
• Automatic electrode diagnosis shows the pH slope and offset
• Solution temperature coefficient compensates for the pure water samples and references the pH to 25°C
ORP
• 1 point offset calibration allows adjusting the displayed value to a known standard
• Relative and absolute millivolt modes ensure the reliable ORP measurements
Infitek Bep-M Series Benchtop pH Lon ORP Water Hardness MeterInfitek Bep-M Series Benchtop pH Lon ORP Water Hardness Meter
Ion Concentration
• 2 to 5 points calibration, including the 8 concentration points can be selected
• Electrode management is capable of storing and recalling up to 3 electrode slopes
• Automatic electrode diagnosis shows the calibration points and slopes
• Selectable ion measurement methods (direct reading, known addition, known subtraction, sample addition, sample subtraction) and concentration units (ppm, mg/L, mol/L or mol/L)
Water Hardness
• 2 to 5 points calibration from low to high concentrations
• Selectable measurement units(German degree, English degree,French degree,mmol/L and mg/L) are used for professional water hardness measurements
General Features
• Automatic temperature compensation ensures accurate readings over the entire range
• Auto-Read function senses and locks the measurement endpoint
• Timed Interval Readings sends the measurement data to a PC or printer
• Limit Alarm automatically alerts when reading exceeds the specified range
• Calibration due alarm prompts user to calibrate the meter regularly
• Password protection prevents the unauthorized calibration and settings
• Expanded memory stores or recalls up to 1000 data sets


Infitek Bep-M Series Benchtop pH Lon ORP Water Hardness MeterInfitek Bep-M Series Benchtop pH Lon ORP Water Hardness Meter

Specification
  
Model BEP-M120 BEP-M130  BEP-M131
pH Range -2.000-20.000pH _
Resolution 0.001,0.01, selectable _
Accuracy ±0.002pH _
Calibration Points 1 to 5 points _
Ph Buffer Options USA, NIST, DIN, 5 custom buffers _
ORP mV Range ±2000.0mV
Relative mV Range ±2000.0mV _
Resolution 0.1mV
Accuracy ±0.2mV
Calibration Points 1 point _
Ion Range 0.001~30000 (depending on the range of ISE) _
Resolution 0.001,0.01,0.1,1 _
Accuracy ±0.5% F.S. (monovalent), ±1% F.S. (divalent)) _
Measurement
Units
ppm, mg/L, mol/L, mmol/L _
Calibration Points 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) _
Measurement Methods
 
Direct reading, known addition, known subtraction, sample addition, sample subtraction _
Electrode Management 1 to 3 electrodes _
Water Hardness Range 0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) _
Resolution 0.001,0.01,0.1,1 _
Accuracy ±1% F.S. _
Calibration Points 2to 5points 0.01,0.1,1.10,100mmol/L) _
Temperature Range 0~105°C/32~221°F
Resolution 0.1°C/0.1°F
Accuracy ±05°C/0.9°F
Offset Calibration 1 point, reading ±10°C
Other Specifications Temperature Compensation 0~100°C, manual or automatic
Solution Temperature Coefficient 25°C _
Stability Criteria Standard or high-accuracy
Calibration Due Alarm 1to 31 days or off
Interval Readings 10, 30, 60 seconds, 10, 30 minutes or off
Password Protection 4digits
Memory 1000 data sets
Communication Interface USB
Connector BNC, 3.5 mm jack socket
Display 7 inches TFT LCD
Power Requirements DC12V power adapter
Dimensions 240(L)× 220 (W)× 80(H)mm
Weight 1.7kg
Packaging & Shipping

Infitek Bep-M Series Benchtop pH Lon ORP Water Hardness Meter
 

 

Certifications

Infitek Bep-M Series Benchtop pH Lon ORP Water Hardness Meter

Company Profile

Infitek Bep-M Series Benchtop pH Lon ORP Water Hardness MeterInfitek Bep-M Series Benchtop pH Lon ORP Water Hardness Meter

FAQ

Q: How about quality of the goods?
A:

  1. All the running products comply with CE standards.
  2. Independent quality inspection team, conducting multiple inspections and random inspections from parts supply to product dispatch.
  3. Well-known third-party testing service available, such as SGS, BV, and TUV, etc.
 
Q: What are your pre- and after-sales services?
A:
  1. Timely reply to pre-sales enquiries
  2. Real-time update of manufacturing and shipment status
  3. Contracted third-party maintenance company in over 60 countries

Assured availability of parts supply for 10 years at least

Q: Is OEM service available.
A: Most of the running products are available for OEM customization, including logo, package and function, if attainable, customization.
 
Q: How long is the lead time:
A: Generally, the lead time for most stocked products is about 7~15 days, vary by models and production schedule. For those non-stocked products, the manufacturing lead time is around 20 days.
Infitek Bep-M Series Benchtop pH Lon ORP Water Hardness Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier