Basic Info.

Model NO.
Aea-H50
Measuring Range1
Hc: 0~10000*10-6(Ppm)Vol
Measuring Range2
Co: 0~10*10-2(%)Vol )
Measuring Range3
CO2: 0~20*10-2(%)Vol
Measuring Range4
O2: 0~25*10-2(%)Vol
Measuring Range5
Nox: 0~5000*10-6(Ppm)Vol
Transport Package
High-Quality Cartons/Crates
Trademark
Infitek
Origin
China
Production Capacity
200 Units/Month

Product Description

Infitek Automobile Exhaust Analyzer Aea-H501

Infitek Automobile Exhaust Analyzer AEA-H501

Features
  1. Separated structural design, operation more convenient and more accurate data.
  2. Adopted a triage-type sampling technique, diesel engine acceleration, deceleration, and steady speed can be measured when the smoke;
  3. Linear automatic data processing, can be displayed opacity degrees N, light absorption coefficient K and the corresponding value of filter paper-type smoke SF;
  4. High-brightness digital display;
  5. Use of "air curtain" technology to protect the optical system from contamination;
  6. Automatic detection of room temperature control, anti-condensation can affect the test accuracy;
  7. Automatically attached to the time display; optional speed measurement and oil temperature measurement
  8. Show where the failure of automatic diagnosis unit;
  9. Equipped with built-in printer (or Bluetooth / RS232);
  10. In line with ISO11614 and GB3847-2018 technical requirements.
Specification
 
Measuring range HC: 0~10000×10-6(ppm)vol
CO: 0~10×10-2(%)vol )
CO2: 0~20×10-2(%)vol
O2: 0~25×10-2(%)vol
NOx: 0~5000×10-6(ppm)vol
Lambda: 0.50~3.00
COcor:0~10×10-2(%)vol
Indicating error HC±12×10-6(ppm)vol ( absolute error ) or±5% ( relative error )
CO±0.06×10-2(%)vol ( absolute error ) or±5% ( relative error )
CO2±0.5×10-2(%)vol ( absolute error ) or±5% ( relative error )
O2±0.1×10-2(%)vol ( absolute error ) or±5% ( relative error )
NOx±25×10-6 (ppm)vol ( absolute error ) or±4% ( relative error )
Stability moment drift≤±3%
Repeatability ≤±2%
Resolution HC:1*10-6(ppm)vol
CO: 0.01*10-2(%)vol
CO2: 0.1*10-2(%)vol
O2: 0.01*10-2(%)vol
NOx: 1×10-6(ppm)vol
Lambda: 0.01
Response time 95% response is not more than 10 seconds
Preheating time 8min ( preheating 3min emergency detection )
Output mode digital direct reading, gases can be attached printer name, the maximum concentration, average value, minimum value, test time, date. Can interface with computer networking
Use temperature  -5~50°C,
Relative humidity ≤90%
Power AC100~240V 50/60Hz or DC12V( Add power inverter)
Power consumption 40VA
Dimension 420 (L )*310(W)*170(H)mm
Weight 9kg
 
Packaging & Shipping

Infitek Automobile Exhaust Analyzer Aea-H501

Certifications

Infitek Automobile Exhaust Analyzer Aea-H501

About us

Infitek Automobile Exhaust Analyzer Aea-H501Infitek Automobile Exhaust Analyzer Aea-H501

FAQ

1. Is our Biochemistry Analyzer an open system?
Yes
2. Does the Biochemistry Analyzer have the ability to detect dirty test tubes and clean them?
No, the Biochemistry Analyzer tests the blood drawn
3. Can the Biochemistry Analyzer be used for animals?
Yes, it can be tested with the corresponding biochemical reagents.
4. Can our Biochemistry Analyzer be connected to the LIS (Laboratory Information System) system?
Yes
5. How many times can our semi-automatic Biochemistry Analyzer perform tests an hour?
There is no way to determine this, because the semi-automatic Biochemistry Analyzer is manual, and the customer's hand speed and sample test time are different. For the same sample, the test can be done one by one; if it is a different sample, after sample A is done, for example, if the result of the first sample comes out, you first need to clean the pipeline and colorimetric cell. After cleaning, you can test The second sample.
6. What are the supported languages?
The semi-automatic Biochemistry Analyzer is currently only available in Russian, English, Portuguese, Spanish, and Chinese. If there are special language requirements, we can send a translation package. After the customer has translated it, we can generate it in the software;
The automatic Biochemistry Analyzer directly mentions the language requirements, and the order can be completed.Infitek Automobile Exhaust Analyzer Aea-H501

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now