Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Fetal Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ECG | Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V) |
Lead selection: I, II, III, avR, avL, avF, V, | |
Waveform: 2 ch | |
Lead mode: 3 Leads ( R, L, F or RA, LA, LL) | |
Lead selection: I, II, III, | |
Waveform: 1 ch | |
Gain: ′2.5mm/mV, ′5.0mm/mV, ′10mm/mV, ′20mm/mV, auto | |
HR and Alarm | |
Range Adult: 15 ~ 300 bpm | |
Neo/Ped: 15 ~ 350 bpm | |
Accuracy : ± 1% or ± 1bpm,which great | |
Resolution: 1 bpm | |
Sensitivity: > 200 (uV P-P) | |
Differential Input Impedance: > 5 MΩ | |
CMRR | Monitor: > 105 dB |
Operation: > 105 dB | |
Diagnosis: > 85 dB | |
Electrode offset potential: ±300mV | |
Leakage Current: < 10 uA | |
Baseline Recovery: < 3 S After Defi. | |
ECG Signal Range: ±8 m V ( Vp-p ) | |
Bandwidth | |
Surgery: 1 ~ 15 Hz | |
Monitor: 0.5 ~ 35 Hz | |
Diagnostic: 0.05 ~ 100 Hz | |
Calibration Signal: 1 (mV p-p), Accuracy:±5% | |
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV | |
ARR Detecting | |
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, | |
TACHY, BRADY, MISSED BEATS, PNP, PNC | |
Alarm: Available | |
Review: Available | |
RESP | Method: Impedance between R-F(RA-LL) |
Differential Input Impedance: >2.5 MΩ | |
Measuring Impedance Range: 0.3~5.0Ω | |
Base line Impedance Range: 0 - 2.5 KΩ | |
Bandwidth: 0.3 ~ 2.5 Hz | |
Resp. Rate | Measuring and Alarm Range |
Adult: 0 ~ 120 rpm | |
Neo/Ped: 0 ~ 150 rpm | |
Resolution: 1 rpm | |
Accuracy : ±2 rpm | |
Apean Alarm: 10 ~ 40 S | |
NIBP | Method: Oscillometric |
Mode: Manual, Auto, STAT | |
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) | |
Measuring Period in STAT Mode: 5 Min | |
Pulse Rate Range: 40 ~ 240 bpm | |
Alarm Type: SYS, DIA, MEAN | |
Measuring and alarm range | |
Adult Mode | |
SYS: 40 ~ 270 mmHg | |
DIA: 10 ~ 215 mmHg | |
MEAN: 20 ~ 235 mmHg | |
Pediatric Mode | |
SYS: 40 ~ 200 mmHg | |
DIA: 10 ~ 150 mmHg | |
MEAN:20 ~ 165 mmHg | |
Neonatal Mode | |
SYS: 40 ~ 135 mmHg | |
DIA:10 ~ 100 mmHg | |
MEAN:20 ~ 110 mmHg | |
Resolution Pressure:1mmHg | |
Accuracy Pressure Maximum Mean error: ±5mmHg | |
Maximum Standard deviation: ±8mmHg | |
Overpressure Protection | |
Adult Mode: 297±3 mmHg | |
Pediatric Mode: 240±3 mmHg | |
Neonatal Mode: 147±3 mmHg | |
SpO2 | Measuring Range: 0 ~ 100 % |
Alarm Range: 0 ~ 100 % | |
Resolution: 1 % | |
Accuracy : 70% ~ 100% ±2 % | |
0% ~ 69% unspecified | |
Actualization interval: about 1 Sec. | |
Alarm Delay: 10 Sec. | |
Pulse Rate | |
Measuring and Alarm Range: 20~300bpm | |
Resolution: 1bpm | |
Accuracy : ±2bpm | |
TEMPERATURE | |
Channel: 2 | |
Measuring and Alarm Range: 0 ~ 50 °C | |
Resolution: 0.1°C | |
Accuracy : ±0.1°C | |
Average Time Constant:<10 Sec. | |
IBP | Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
ART: 0 ~ 300 mmHg | |
PA: -6 ~ 120 mmHg | |
CVP/RAP/LAP/ICP: -10 ~ 40 mmHg | |
P1/P2: -10 ~ 300 mmHg | |
Press Sensor | |
Sensitivity: 5 uV/V/mmHg | |
Impedance: 300-3000Ω | |
Resolution: 1 mmHg | |
Accuracy : ±2% or ±1mmHg, which great | |
Actualization interval: about 1 Sec | |
Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature | |
Optional: Nellcor SpO2, EtCO2,IBP, Touch screen, Thermal Recorder,Wall mount, Trolley, Central station,VGA |
Q: Are you a trading company or a manufacturer?
A: Based on independent manufacturing capability, we also integrate both domestic and international resources providing one-stop service for you all.
Q: How about quality of the goods?
A:
l All the running products comply with CE standards.
l Independent quality inspection team, conducting multiple inspections and random inspections from parts supply to product dispatch.
l Well-known third-party testing service available, such as SGS, BV, and TUV, etc.
Q: What are your pre- and after-sales services?
A:
l Timely reply to pre-sales enquiries
l Real-time update of manufacturing and shipment status
l Contracted third-party maintenance company in over 60 countries
Assured availability of parts supply for 10 years at least
Q: Is OEM service available.
A: Most of the running products are available for OEM customization, including logo, package and function, if attainable, customization.
Q: How long is the lead time: