• Infitek Patient Monitor, Pm-15D
  • Infitek Patient Monitor, Pm-15D
  • Infitek Patient Monitor, Pm-15D
  • Infitek Patient Monitor, Pm-15D
  • Infitek Patient Monitor, Pm-15D
  • Infitek Patient Monitor, Pm-15D

Infitek Patient Monitor, Pm-15D

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Fetal Monitor
Group: All
Transport Package: Cartons
Specification: /
Trademark: Infitek
Customization:
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (20)
  • Overview
  • Features
  • Specification
  • Certifications
  • Packaging & Shipping
  • About us
  • FAQ
Overview

Basic Info.

Model NO.
PM-15D
Origin
China
Production Capacity
200 Units/Month

Product Description

Infitek Patient Monitor, Pm-15DInfitek Patient Monitor, PM-15D
 
Features
  1. 15″ high resolution color TFT LCD display
  2. 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable
  3. Efficient resistance to interference of defibrillator and electrosurgical cautery
  4. SPO2 can testing for 0.1% Weak
  5. RA-LL impedance Respiration
  6. Trend Coexist Display
  7. OxyCRG DyNamic View Display
  8. Bed to Bed view Display
  9. Networking capacity
  10. Options of printing, IBP, VGA and EtCO2
  11. UP to 4 hours working capacity of built_in rechargeable battery
  12. Large volume of tabular and graphic trends information storage and easy to recall
  13. Anti-ESU, anti- defibrillator
  14. Capture dynamic waveforms.
Specification
ECG Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2 ch
Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
Lead selection: I, II, III,
Waveform: 1 ch
Gain: ′2.5mm/mV, ′5.0mm/mV, ′10mm/mV, ′20mm/mV,  auto
HR and Alarm
Range Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy : ± 1% or ± 1bpm,which great
Resolution: 1 bpm
Sensitivity: > 200 (uV P-P)
Differential Input Impedance: > 5 MΩ
CMRR Monitor: > 105 dB
Operation: > 105 dB
Diagnosis: > 85 dB
Electrode offset potential: ±300mV
Leakage Current: < 10 uA
Baseline Recovery: < 3 S  After Defi.
ECG Signal Range: ±8 m V ( Vp-p )
Bandwidth
Surgery: 1 ~ 15 Hz
Monitor: 0.5 ~ 35 Hz
Diagnostic: 0.05 ~ 100 Hz
Calibration Signal: 1 (mV p-p),  Accuracy:±5%
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC,
TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: Available
Review: Available
RESP Method: Impedance between R-F(RA-LL)
Differential Input Impedance: >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 - 2.5  KΩ
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Rate Measuring and Alarm Range
Adult: 0 ~ 120 rpm
Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy : ±2 rpm
Apean Alarm: 10 ~ 40 S
NIBP Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS: 40 ~ 270 mmHg
DIA: 10 ~ 215 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric Mode
SYS: 40 ~ 200 mmHg
DIA: 10 ~ 150 mmHg
MEAN:20 ~ 165 mmHg
Neonatal Mode
SYS: 40 ~ 135 mmHg
DIA:10 ~ 100 mmHg
MEAN:20 ~ 110 mmHg
Resolution Pressure:1mmHg
Accuracy  Pressure  Maximum Mean error: ±5mmHg
Maximum Standard deviation: ±8mmHg
Overpressure Protection
Adult Mode: 297±3 mmHg
Pediatric Mode: 240±3 mmHg
Neonatal Mode: 147±3 mmHg
SpO2 Measuring Range: 0 ~ 100 %
Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy : 70% ~ 100% ±2 %
0% ~ 69% unspecified
Actualization interval: about 1 Sec.
Alarm Delay: 10 Sec.
Pulse Rate
Measuring and Alarm Range: 20~300bpm
Resolution: 1bpm
Accuracy : ±2bpm
TEMPERATURE
Channel: 2
Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1°C
Accuracy : ±0.1°C
Average Time Constant:<10 Sec.
IBP Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
ART: 0 ~ 300 mmHg
PA: -6 ~ 120 mmHg
CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
P1/P2: -10 ~ 300 mmHg
Press Sensor
Sensitivity: 5 uV/V/mmHg
Impedance: 300-3000Ω
Resolution: 1 mmHg
Accuracy : ±2% or ±1mmHg, which great
Actualization interval: about 1 Sec
Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO2,IBP, Touch screen, Thermal Recorder,Wall mount, Trolley, Central station,VGA
Certifications

 

Infitek Patient Monitor, Pm-15D
Packaging & Shipping

Infitek Patient Monitor, Pm-15D

About us

 

Infitek Patient Monitor, Pm-15D
FAQ

Q: Are you a trading company or a manufacturer?

A: Based on independent manufacturing capability, we also integrate both domestic and international resources providing one-stop service for you all.

 

Q: How about quality of the goods?

A:

All the running products comply with CE standards.

Independent quality inspection team, conducting multiple inspections and random inspections from parts supply to product dispatch.

Well-known third-party testing service available, such as SGS, BV, and TUV, etc.

 

Q: What are your pre- and after-sales services?

A:

Timely reply to pre-sales enquiries

Real-time update of manufacturing and shipment status

Contracted third-party maintenance company in over 60 countries

Assured availability of parts supply for 10 years at least

 

Q: Is OEM service available.

A: Most of the running products are available for OEM customization, including logo, package and function, if attainable, customization.

 

Q: How long is the lead time:

A: Generally, the lead time for most stocked products is about 7~15 days, vary by models and production schedule. For those non-stocked products, the manufacturing lead time is around 20 days.

Infitek Patient Monitor, Pm-15D
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now