Infitek Benchtop Lab Benchtop Grating Spectrophotometer with FDA Approved
1, High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Bluetooth 2.1; Concave Grating.
2, Double Array 256 Image Element CMOS Sensor; Long life-span stable LED, UV LED.
3, With reflective and transmissive spectrum, and accurate Lab value, it is good to calculate color formula and do precise color transmission.
4, Auto identify measured aperture. Freely switchable between 4 measured apertures: φ25.4mm/15mm/8mm/4mm. Users also can customize apertures.
5, Built-in temperature sensor to monitor and compensate the measuried temperature to ensure the measurement more precision.
6, Wavelength range 360nm - 780nm. Built-in 400nm cut off/420nm cut off/460nm cut off (only xenon lamp edition), more professional in UV measurement.
7, Independent light source detector, can continuously monitor the condition of light sources to ensure the light source reliable.
8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users' requirements.
9,A variety of optional accessories: Reflection sample holding tool, transmission fixture, micro 4mm aperture transmission test components, and instrument inversion test components, applicable to more working conditions;
10, Big capacity data storage, for 40000 pieces test result.
11, Built-in camera locating.
12, More powerful extended functions at the PC software.
Application Industry
SP-CLR606 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, electronics, paint and ink, printing, garments, leather, paper, auto, medical, cosmetics, food, science institutes, and laboratories.
Model | SP-CLR606 |
Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source; Haze(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
Application | It is used for accurate analysis and transmission of laboratory color.It can be applied in paints, inks, textiles, garments, printing and dyeing, printing and other industries for color transfer and quality control. |
Integrating Sphere Size | Φ154mm |
Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nmCut-off light source |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Interval | 10nm |
Semiband Width | 5nm |
Measured Reflectance Range | 0-200% |
Measured Aperture | Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; Transmissive : Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position |
Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
Color Difference Formula | ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter), |
Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM E313, CIE/ISO), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness,Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003) Saybolt, Color Code (ASTM D1500) |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measurement Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%) Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.12 |
(Average for 12 BCRA Series II color tiles) | |
Dimension | L*W*H=370x300x200mm |
Weight | Approx. 9.6kg |
Power | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB & Bluetooth & Print serial port |
Data Storage | Standard 5000 Pcs, Sample 40000 Pcs |
Language | Simplified Chinese, Traditional Chinese, English, (Optional Customized German, French and Spanish) |
Operating Environment | 0~40ºC, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50ºC, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component |
Optional Accessory | Micro Aperture(4mm) transmission test clamp component |
Notes: | The specifications are subject to change without notice. |
Q: How about quality of the goods?
A:lAll the running products comply with CE standards.
lIndependent quality inspection team, conducting multiple inspections and random inspections from parts supply to product dispatch.
lWell-known third-party testing service available, such as SGS, BV, and TUV, etc.
Q: What are your pre- and after-sales services?
A:lTimely reply to pre-sales enquiries
lReal-time update of manufacturing and shipment status
lContracted third-party maintenance company in over 60 countries
lAssured availability of parts supply for 10 years at least
Q: Is OEM service available.
A: Most of the running products are available for OEM customization, including logo, package and function, if attainable, customization.
Q: How long is the lead time:
A: Generally, the lead time for most stocked products is about 7~15 days, vary by models and production schedule. For those non-stocked products, the manufacturing lead time is around 20 days.